Description
Vehicle specification needs to be written with M.U.T.-III SE because it is not written after replacing the power steering control module.
The configuration requires network connection. M.U.T.-III SE connects to network and then it downloads the configuration data from the server. Then M.U.T.-III SE writes the vehicle specification to the power steering control module.
Refer to Work Procedure.
noteFor details the network connection and operation, refer to “M.U.T.-III SE Operation Manual”.
The configuration no need to “save” configuration data from the power steering control module. The configuration data is always generated freshly at the server and then downloaded to the M.U.T.-III SE.
caution
  • Complete the procedure of “Configuration” in order.
  • If incorrect “Configuration”, incidents might occur.
  • Never perform “Configuration” except for new power steering control module.