2.CHECK PARKING BRAKE ACTUATOR CIRCUIT (1)
3.CHECK PARKING BRAKE ACTUATOR CIRCUIT (2)
Check the continuity between parking brake actuator (LH) harness connector terminals.Terminal | Continuity |
1 – 2 | Existed |
Is the inspection result normal?
Repair/replace harness or connector.
4.CHECK MOTOR POWER SUPPLY
5.CHECK MOTOR POWER SUPPLY CIRCUIT
- Disconnect 12V battery negative terminal.
- Check the 50A fuse (#L).
- Check the continuity and short circuit between ABS actuator and electric unit (control unit) harness connector terminal (30) and 50A fuse (#L).
Is the inspection result normal?
Perform trouble diagnosis for 12V battery power supply. Repair/replace harness, connector or fuse.
6.CHECK ABS ACTUATOR AND ELECTRIC UNIT (CONTROL UNIT) GROUND CIRCUIT
8.PERFORM SELF-DIAGNOSIS
With M.U.T.-III SE- Connect the parking brake actuator (LH) harness connector.
- Connect the ABS actuator and electric unit (control unit) harness connector.
- Connect 12V battery negative terminal.
- Ignition switch ON.
- Apply and release the parking brake five times.
- Perform self-diagnosis for “ABS”.
Is DTC “C10B1-01” detected?
-2
"PAST" is displayed: INSPECTION END (Erase the memory of self-diagnosis results.)INSPECTION END