Component Inspection (Motor Coil A)
1.
CHECK MOTOR COIL A
note
If the electric shift selector is shifted before disconnecting the shift actuator connector, wait at least 5 minutes.
Disconnect the shift actuator connector.
Check the resistance between shift actuator connector terminals.
Shift actuator
Condition
Resistance
Motor coil
Terminal
A
5
6
Coil temperature: 20°C (68°F)
2.3 – 2.8 Ω
7
8
Is the inspection result normal?
INSPECTION END
Replace the transaxle assembly due to malfunction in the motor coil A (shift actuator). Refer to Remove and Installation
Removal and Installation
.