Component Inspection (Shift Actuator Relay A)
1.
CHECK SHIFT ACTUATOR RELAY A
Disconnect the shift actuator relay. Refer to
Component Parts Location
.
Apply 12 V direct current between shift actuator relay terminals 8 and 9.
caution
Never make the terminals short.
Connect the fuse between the terminals when applying the voltage.
Check the continuity between shift actuator relay terminals 6 and 7.
Shift actuator relay
Condition
Continuity
Terminal
6
7
Apply 12 V direct current between terminals 8 and 9.
Existed
Does not apply 12 V direct current between terminals 8 and 9.
Not existed
Is the inspection result normal?
INSPECTION END
Replace the shift actuator relay.