[Previous][Next]
Component Inspection (P Position Switch)
1.CHECK P POSITION SWITCH
  1. Disconnect the electric shift selector connectors.
  2. Check the continuity between electric shift selector connector terminals.
    Electric shift selectorConditionContinuity
    P position switchTerminal
    No. 116When P position switch is pressedExisted
    When P position switch is releasedNot existed
    No. 21318When P position switch is pressedNot existed
    When P position switch is releasedExisted
Is the inspection result normal?
INSPECTION END
Replace the electric shift selector due to malfunction in the P position switch. Refer to Removal and Installation.