Work Procedure
1.
PERFORM CALIBRATION OF DECEL G SENSOR [ABS actuator and electric unit (control unit)]
Perform calibration of decel G sensor. Refer to Description
Description
.
:
.
2.
PREPARATION BEFORE CALIBRATION PROCEDURE
Park the vehicle on a level surface.
Adjust air pressure of all tires to the specified pressure. Refer to
Tire Air Pressure
.
:
.
3.
PERFORM CALIBRATION OF DECEL G SENSOR (TCM)
With M.U.T.-III SE
The ignition switch is ON.
caution
Never start engine.
Select “Special Function” in “TRANSMISSION”.
Select “G SENSOR CALIBRATION” of “G sensor calibration”.
Touch “OK”.
caution
Never rock or jounce the vehicle during “G sensor calibration”.
Is “COMPLETED” displayed?
WORK END
Perform steps 3 again.