[Previous][Next]
Work Procedure
1.PERFORM CALIBRATION OF DECEL G SENSOR [ABS actuator and electric unit (control unit)]
Perform calibration of decel G sensor. Refer to DescriptionDescription.
: .
 
2.PREPARATION BEFORE CALIBRATION PROCEDURE
  1. Park the vehicle on a level surface.
  2. Adjust air pressure of all tires to the specified pressure. Refer to Tire Air Pressure.
: .
 
3.PERFORM CALIBRATION OF DECEL G SENSOR (TCM)
With M.U.T.-III SE
  1. The ignition switch is ON.
    cautionNever start engine.
  2. Select “Special Function” in “TRANSMISSION”.
  3. Select “G SENSOR CALIBRATION” of “G sensor calibration”.
  4. Touch “OK”.
    cautionNever rock or jounce the vehicle during “G sensor calibration”.
Is “COMPLETED” displayed?
WORK END
Perform steps 3 again.