Monitor item | Condition | Value / Status |
Shift sensor 1 voltage | Selector lever is held in H (Home), R, and Nr positions | 1.08 - 2.12 V |
Other than the above | 2.68 - 3.28 V | |
Shift sensor 2 voltage | Selector lever is held in H (Home), R, and Nr positions | 1.08 - 2.12 V |
Other than the above | 2.68 - 3.28 V | |
Shift sensor 3 voltage | Selector lever is held in H (Home) and Nr positions | 1.08 - 2.12 V |
Other than the above | 2.68 - 3.28 V | |
Shift sensor 4 voltage | Selector lever is held in H (Home), Nr, and Nd positions | 1.08 - 2.12 V |
Other than the above | 2.68 - 3.28 V | |
Shift sensor 5 voltage | Selector lever is held in H (Home), Nr, and Nd positions | 1.08 - 2.12 V |
Other than the above | 2.68 - 3.28 V | |
Shift sensor 6 voltage | Selector lever is held in H (Home) and Nd positions | 1.08 - 2.12 V |
Other than the above | 2.68 - 3.28 V | |
Shift sensor 7 voltage | Selector lever is held in H (Home), D/M, and Nd positions | 1.08 - 2.12 V |
Other than the above | 2.68 - 3.28 V | |
Shift sensor 8 voltage | Selector lever is held in H (Home), D/M, and Nd positions | 1.08 - 2.12 V |
Other than the above | 2.68 - 3.28 V |
Electric shift sensor | + | − | Condition | Voltage (Approx.) | |
Electric shift control module | |||||
Connector | Terminal | ||||
1 | E131 | 34 | Ground | Selector lever is held in H (Home), R, and Nr positions | 1.08 - 2.12 V |
Other than the above | 2.68 - 3.28 V | ||||
2 | 35 | Selector lever is held in H (Home), R, and Nr positions | 1.08 - 2.12 V | ||
Other than the above | 2.68 - 3.28 V | ||||
3 | 36 | Selector lever is held in H (Home) and Nr positions | 1.08 - 2.12 V | ||
Other than the above | 2.68 - 3.28 V | ||||
4 | 37 | Selector lever is held in H (Home), Nr, and Nd positions | 1.08 - 2.12 V | ||
Other than the above | 2.68 - 3.28 V | ||||
5 | 44 | Selector lever is held in H (Home), Nr, and Nd positions | 1.08 - 2.12 V | ||
Other than the above | 2.68 - 3.28 V | ||||
6 | 45 | Selector lever is held in H (Home) and Nd positions | 1.08 - 2.12 V | ||
Other than the above | 2.68 - 3.28 V | ||||
7 | 39 | Selector lever is held in H (Home), D/M, and Nd positions | 1.08 - 2.12 V | ||
Other than the above | 2.68 - 3.28 V | ||||
8 | 40 | Selector lever is held in H (Home), D/M, and Nd positions | 1.08 - 2.12 V | ||
Other than the above | 2.68 - 3.28 V |
+ | − | Condition | Voltage (Approx.) | |
Electric shift selector | ||||
Connector | Terminal | |||
M2 | 1 | Ground | Ignition switch is ON | 5 V |
13 |
+ | – | Voltage (Approx.) | |
Electric shift control module | |||
Connector | Terminal | ||
E130 | 19 | Ground | 0 V |
E131 | 48 |
Electric shift control module | Electric shift control module | Continuity | ||
Connector | Terminal | Connector | Terminal | |
E130 | 19 | E130 | Except 19 | Not existed |
E131 | 48 | E131 | Except 48 |
Electric shift control module | Electric shift selector | Continuity | ||
Connector | Terminal | Connector | Terminal | |
E131 | 41 | M2 | 12 | Existed |
50 | 24 |
Electric shift control module | — | Continuity | |
Connector | Terminal | ||
E131 | 41 | Ground | Not existed |
50 |
Electric shift sensor | + | – | Voltage (Approx.) | |
Electric shift control module | ||||
Connector | Terminal | |||
1 | E131 | 34 | Ground | 0 V |
2 | 35 | |||
3 | 36 | |||
4 | 37 | |||
5 | 44 | |||
6 | 45 | |||
7 | 39 | |||
8 | 40 |
Electric shift sensor | Electric shift control module | Electric shift control module | Continuity | ||
Connector | Terminal | Connector | Terminal | ||
1 | E131 | 34 | E131 | Except 34 | Not existed |
2 | 35 | Except 35 | |||
3 | 36 | Except 36 | |||
4 | 37 | Except 37 | |||
5 | 44 | Except 44 | |||
6 | 45 | Except 45 | |||
7 | 39 | Except 39 | |||
8 | 40 | Except 40 |