[Previous][Next]
Work Procedure (Group A)
*1:When the same malfunction is detected in two consecutive trips, MIL will illuminate.
1.CHECK DTC
Check DTC.
Is any DTC detected?
Repair malfunction(s) and erase DTC. Refer to "DTC Index" of each Control module.
.
 
2.CHECK PERMANENT DTC
With M.U.T.-III SE
  1. Turn ignition switch OFF and wait at least 10 seconds.
  2. Turn ignition switch ON.
  3. Turn ignition switch OFF and wait at least 10 seconds.
  4. Turn ignition switch ON.
  5. Select “PERMANENT DTC STATUS” mode with M.U.T.-III SE.
 
With GST
  1. Turn ignition switch OFF and wait at least 10 seconds.
  2. Turn ignition switch ON.
  3. Turn ignition switch OFF and wait at least 10 seconds.
  4. Turn ignition switch ON.
  5. Select Service $0A with GST.
 
Is any permanent DTC detected?
.
END
 
3.PERFORM DTC CONFIRMATION PROCEDURE
Perform “DTC CONFIRMATION PROCEDURE” for DTCs which are the same as permanent DTCs stored in ECM. Refer to DTC Index.
: .
 
4.CHECK PERMANENT DTC
With M.U.T.-III SE
  1. Turn ignition switch OFF and wait at least 10 seconds.
  2. Turn ignition switch ON.
  3. Turn ignition switch OFF and wait at least 10 seconds.
  4. Turn ignition switch ON.
  5. Select “PERMANENT DTC STATUS” mode with M.U.T.-III SE.
 
With GST
  1. Turn ignition switch OFF and wait at least 10 seconds.
  2. Turn ignition switch ON.
  3. Turn ignition switch OFF and wait at least 10 seconds.
  4. Turn ignition switch ON.
  5. Select Service $0A with GST.
 
Is any permanent DTC detected?
.
END