[Previous][Next]
Mass Air Flow Sensor (With Intake Air Temperature Sensor)
 
 
MASS AIR FLOW SENSOR
The mass air flow sensor is placed in the stream of intake air. It measures the intake flow rate by measuring a part of the entire intake flow. The MAF sensor controls the temperature of the heater in sensing element to a certain amount. The temperature distribution around the heater changes according to the increase in intake air volume. The change is detected by a thermistor and the air volume data is sent to ECM by the MAF sensor.
 
 
INTAKE AIR TEMPERATURE SENSOR
The intake air temperature sensor is built-into mass air flow sensor. The sensor detects intake air temperature and transmits a signal to the ECM.
The temperature sensing unit uses a thermistor which is sensitive to the change in temperature.
<Reference data>
Intake air temperature
[°C (°F)]
Voltage* (V)
25 (77)1.9 – 2.1
80 (176)3.0 – 3.2
*: These data are reference values on the diagnosis tool.