Work Procedure
1.
START
With M.U.T.-III SE
Turn ignition switch ON.
Select "CLSD THL POS LEARN" in "Learning" (in "Special Function") mode of "ENGINE" using M.U.T.-III SE.
Follow the instructions on the M.U.T.-III SE display.
Turn ignition switch OFF and wait at least 10 seconds.
Check that throttle valve moves during the above 10 seconds by confirming the operating sound.
Without M.U.T.-III SE
Start the engine.
note
Engine coolant temperature is 25°C (77°F) or less before engine starts.
Warm up the engine.
note
Raise engine coolant temperature until it reaches 65°C (149°F) or more.
Turn ignition switch OFF and wait at least 10 seconds.
Check that throttle valve moves during the above 10 seconds by confirming the operating sound.
:
END