1.CHECK DTC PRIORITY
If DTC P119B is displayed with DTC P06B0, first perform trouble diagnosis for DTC P0192 or P0193.Is applicable DTC detected?
.
2.CHECK FUEL RAIL PRESSURE (FRP) SENSOR POWER SUPPLY-1
- Turn ignition switch OFF.
- Disconnect FRP sensor connector.
- Turn ignition switch ON.
- Check the voltage between FRP sensor harness connector terminals.
FRP sensor | Voltage (Approx.) |
Connector | + | − |
Terminal |
F79 | 3 | 1 | 5 V |
Inspection result normal?
3.CHECK FRP SENSOR POWER SUPPLY-2
Check the voltage between FRP sensor harness connector and the ground.+ | − | Voltage (Approx.) |
FRP sensor |
Connector | Terminal |
F79 | 3 | Ground | 5 V |
Is inspection result normal?
4.CHECK FRP SENSOR POWER SUPPLY CIRCUIT FOR OPEN AND SHORT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between FRP sensor harness connector and ECM harness connector.
FRP sensor | ECM | Continuity |
Connector | Terminal | Connector | Terminal |
F79 | 3 | F51 | 61 | Existed |
- Also check harness for short to power.
Is inspection result normal?
Perform trouble diagnosis for power supply circuit. Repair or replace error-detected parts.
5.CHECK FRP SENSOR GROUND CIRCUIT FOR OPEN AND SHORT
6.CHECK ECM GROUND CIRCUIT FOR OPEN AND SHORT
- Check the continuity between ECM harness connector and ground.
ECM | Ground | Continuity |
Connector | Terminal |
F51 | 4 | Ground | Existed |
E16 | 156 |
157 |
160 |
- Also check harness for short to power.
Is the inspection result normal?
INSPECTION END Repair or replace error-detected parts.
7.CHECK FRP SENSOR SIGNAL CIRCUIT FOR OPEN AND SHORT