[Previous][Next]
Diagnosis Procedure
noteTurning the ignition switch ON with FRP sensor harness connector disconnected causes ECM to detect DTC P0192 or P0193. Be sure to erase the DTC when the diagnosis procedure.
1.CHECK DTC PRIORITY
If DTC P119A is displayed with DTC P06B0, first perform trouble diagnosis for DTC P06B0.
Is applicable DTC detected?
Perform diagnosis of applicable. Refer to DTC Diagnosis Procedure.
.
 
2.CHECK FUEL RAIL PRESSURE (FRP) SENSOR POWER SUPPLY-1
  1. Turn ignition switch OFF.
  2. Disconnect FRP sensor connector.
  3. Turn ignition switch ON.
  4. Check the voltage between FRP sensor harness connector terminals.
    FRP sensorVoltage
    (Approx.)
    Connector+
    Terminal
    F79315 V
Inspection result normal?
.
.
 
3.CHECK FRP SENSOR POWER SUPPLY-2
Check the voltage between FRP sensor harness connector and the ground.
+Voltage
(Approx.)
FRP sensor
ConnectorTerminal
F793Ground5 V
Is inspection result normal?
.
.
 
4.CHECK FRP SENSOR POWER SUPPLY CIRCUIT FOR OPEN AND SHORT
  1. Turn ignition switch OFF.
  2. Disconnect ECM harness connector.
  3. Check the continuity between FRP sensor harness connector and ECM harness connector.
    FRP sensorECMContinuity
    ConnectorTerminalConnectorTerminal
    F793F5161Existed
  4. Also check harness for short to power.
Is inspection result normal?
Perform trouble diagnosis for power supply circuit.
Repair or replace error-detected parts.
 
5.CHECK FRP SENSOR GROUND CIRCUIT FOR OPEN AND SHORT
  1. Turn ignition switch OFF.
  2. Disconnect ECM harness connector.
  3. Check the continuity between FRP sensor harness connector and ECM harness connector.
    FRP sensorECMContinuity
    ConnectorTerminalConnectorTerminal
    F791F5141Existed
  4. Also check harness for short to power.
Is inspection result normal?
.
Repair or replace error-detected parts.
 
6.CHECK ECM GROUND CIRCUIT FOR OPEN AND SHORT
  1. Check the continuity between ECM harness connector and ground.
    ECMGroundContinuity
    ConnectorTerminal
    F514GroundExisted
    E16156
    157
    160
  2. Also check harness for short to power.
Is the inspection result normal?
INSPECTION END
Repair or replace error-detected parts.
 
7.CHECK FRP SENSOR SIGNAL CIRCUIT FOR OPEN AND SHORT
  1. Turn ignition switch OFF.
  2. Disconnect ECM harness connector.
  3. Check the continuity between FRP sensor harness connector and ECM harness connector.
    FRP sensorECMContinuity
    ConnectorTerminalConnectorTerminal
    F792F5158Existed
  4. Also check harness for short to ground and to power.
Is inspection result normal?
.
Repair or replace error-detected parts.
 
8.CHECK FRP SENSOR
Check the FRP sensor. Refer to Component Inspection.
Is inspection result normal?
INSPECTION END
Repair or replace error-detected parts.