[Previous][Next]
Diagnosis Procedure
1.CHECK ENGINE OIL PRESSURE
With M.U.T.-III SE
  1. Turn ignition switch ON.
  2. Select “DATA MONITOR” mode of “ENGINE” using M.U.T.-III SE.
  3. Start the engine and check that “EOP SENSOR” changes, according to engine speeds.
    Monitor itemConditionValue
    (Approx.)
    EOP SENSOR
    • Engine oil temperature: 80°C (176°F)
    • Selector lever: P or N position
    • Air conditioner switch: OFF
    • No load
    Engine speed:
    Idle
    1,450 mV or more
    Engine speed:
    2,000 rpm
    2,850 mV or more
Without M.U.T.-III SE
Check oil pressure. Refer to Inspection.
Is the inspection result normal?
.
Check oil passage. Refer to Engine Lubrication System.
 
2.CHECK ENGINE OIL PRESSURE SENSOR POWER SUPPLY
  1. Turn ignition switch OFF.
  2. Disconnect engine oil pressure (EOP) sensor sensor harness connector.
  3. Turn ignition switch ON.
  4. Check the voltage between EOP sensor harness connector and ground.
    +Voltage
    (Approx.)
    EOP sensor
    ConnectorTerminal
    F543Ground5 V
Is the inspection result normal?
.
.
 
3.CHECK ENGINE OIL PRESSURE SENSOR POWER SUPPLY CIRCUIT
  1. Turn ignition switch OFF.
  2. Disconnect ECM harness connector.
  3. Check the continuity between EOP sensor harness connector and ECM harness connector.
    EOP sensorECMContinuity
    ConnectorTerminalConnectorTerminal
    F543F5277Existed
  4. Also check harness for short to ground.
Is the inspection result normal?
Perform the trouble diagnosis for power supply circuit.
Repair or replace error-detected parts.
 
4.CHECK ENGINE OIL PRESSURE SENSOR GROUND CIRCUIT
  1. Turn ignition switch OFF.
  2. Disconnect ECM harness connector.
  3. Check the continuity between EOP sensor harness connector and ECM harness connector.
    EOP sensorECMContinuity
    ConnectorTerminalConnectorTerminal
    F541F52103Existed
  4. Also check harness for short to ground.
Is the inspection result normal?
.
Repair or replace error-detected parts.
 
5.CHECK ENGINE OIL PRESSURE SENSOR INPUT SIGNAL CIRCUIT
  1. Check the continuity between EOP sensor harness connector and ECM harness connector.
    EOP sensorECMContinuity
    ConnectorTerminalConnectorTerminal
    F542F521145 V
  2. Also check harness for short to ground.
Is the inspection result normal?
.
Repair or replace error-detected parts.
 
6.CHECK ENGINE OIL PRESSURE SENSOR
Refer to Component Inspection.
Is the inspection result normal?
Check intermittent incident. Refer to Intermittent IncidentIntermittent Incident.
Replace engine oil pressure sensor.