Diagnosis Procedure
1.
CHECK LVDS CABLE 1
Turn ignition switch OFF.
Check the connection status of the LVDS cable connector. (around view monitor control unit side, wire to wire, and front camera side)
Is inspection result normal?
.
Connect the LVDS cable connector correctly.
2.
CHECK LVDS CABLE 2
Turn ignition switch OFF.
Disconnect around view monitor control unit connector and front camera connector.
Check continuity between around view monitor control unit harness connector and front camera harness connector.
Around view monitor control unit
Front camera
Continuity
Connector
Terminals
Connector
Terminals
B81
39
B84
1
Existed
40
2
Check continuity between around view monitor control unit harness connector and ground.
Around view monitor control unit
Ground
Continuity
Connector
Terminal
B81
39
Not existed
Is inspection result normal?
Replace front camera. Refer to
Removal and Installation
.
Replace LVDS cable.