Component Inspection
1.
CHECK AMBIENT SENSOR
Remove ambient sensor. Refer to
Removal and Installation
.
Check resistance between ambient sensor terminals. Refer to applicable table for the normal value.
Terminal
Condition
Resistance: kΩ
Temperature: °C (°F)
1
2
−20 (−4)
16.50
−10 (14)
9.92
0 (32)
6.19
10 (50)
3.99
20 (68)
2.65
25 (77)
2.19
30 (86)
1.81
40 (104)
1.27
Is the inspection result normal?
INSPECTION END
Replace ambient sensor. Refer to
Removal and Installation
.