[Previous][Next]
Diagnosis Procedure
1.CHECK NETWORK-DTC
Check the CAN diagnosis results from M.U.T.-III SE to see that the ITS CAN communication 4 circuit have no malfunction.
Are the ITS CAN communication 4 circuit normal?
.
Check and repair ITS CAN communication 4 circuit.
 
2.CONNECTOR INSPECTION
  1. Turn the ignition switch OFF.
  2. Disconnect the battery cable from the negative terminal.
  3. Disconnect all the control unit connectors on ITS CAN communication 5 circuit.
  4. Check the terminals and connectors for damage, bend and loose connection.
Is the inspection result normal?
.
Repair the terminal and connector.
 
3.CHECK HARNESS CONTINUITY (OPEN CIRCUIT)
Check the continuity between the around view monitor control unit harness connector and sonar control unit harness connector.
Around view monitor control unit harness connectorSonar control unit harness connectorContinuity
Connector No.Terminal No.Connector No.Terminal No.
B7521B4928Existed
526Existed
Is the inspection result normal?
.
Check the harness and repair or replace the root cause.
 
4.CHECK HARNESS CONTINUITY (SHORT CIRCUIT)
Check the continuity between the around view monitor control unit harness connector terminals.
Around view monitor control unit harness connectorContinuity
Connector No.Terminal No.
B75215Not existed
Is the inspection result normal?
.
Check the harness and repair or replace the root cause.
 
5.CHECK HARNESS CONTINUITY (SHORT CIRCUIT)
Check the continuity between the around view monitor control unit and the ground.
Around view monitor control unit harness connectorGroundContinuity
Connector No.Terminal No.
B7521Not existed
5Not existed
Is the inspection result normal?
.
Check the harness and repair or replace (if shield line is short) the root cause.
 
6.CHECK AROUND VIEW MONITOR CONTROL UNIT AND SONAR CONTROL UNIT TERMINATION CIRCUIT
  1. Remove the around view monitor control unit and the sonar control unit.
  2. Check the resistance between the around view monitor control unit terminals.
    Around view monitor control unitResistance (Ω)
    Terminal No.
    215Approx. 108 – 132
  3. Check the resistance between the sonar control unit terminals.
    Sonar control unitResistance (Ω)
    Terminal No.
    2826Approx. 108 – 132
Is the measurement value within the specification?
.
Replace the around view monitor control unit and/or the sonar control unit.
 
7.CHECK SYMPTOM
Connect all the connectors. Check if the symptoms described in the “Symptom (Results from interview with customer)” are reproduced.
Inspection result
: .
: Start the diagnosis again. Follow the trouble diagnosis procedure when past error is detected.
 
8.CHECK UNIT REPRODUCTION
Perform the reproduction test as per the following procedure for each unit.
  1. Turn the ignition switch OFF.
  2. Disconnect the battery cable from the negative terminal.
  3. Disconnect one of the unit connectors of ITS CAN communication 5 circuit.
    noteAround view monitor control unit and sonar control unit have a termination circuits. Check other units first.
  4. Connect the battery cable to the negative terminal. Check if the symptoms described in the “Symptom (Results from interview with customer)” are reproduced.
    noteAlthough unit-related error symptoms occur, do not confuse them with other symptoms.
Inspection result
: Connect the connector. Check other units as per the above procedure.
: Replace the unit whose connector was disconnected.