[Previous][Next]
Lubricant Adjusting Procedure for Components Replacement Except A/C compressor
Fill with lubricant for the amount that is calculated according to the following conditions.
Example: Lubricant amount to be added when replacing evaporator and condenser & liquid tank [m (Imp fl oz)] = 45 (1.6) + 15 (0.5) + α
ConditionsLubricant amount to be added to A/C system
m (Imp fl oz)
Replace evaporator35 (1.2)
Replace condenser & liquid tank20 (0.7)
Refrigerant leakage is detectedLarge amount leakage30 (1.1)
Small amount leakage
Lubricant amount that is recycled together with refrigerant during recycle operationα