| + | − | Condition | Voltage | |
| TCM | ||||
| Connector | Terminal | |||
| F75 | 17 | Ground |
| 0.7– 0.9V |
INSPECTION END| TCM | CVT unit | Continuity | ||
| Connector | Terminal | Connector | Terminal | |
| F75 | 11 | F74 | 18 | Existed |
| 17 | 13 | |||
| 26 | 22 | |||
Repair or replace malfunctioning parts.| TCM | — | Continuity | |
| Connector | Terminal | ||
| F75 | 17 | Ground | Not existed |
| 26 | |||
Repair or replace malfunctioning parts.
. | CVT unit | Control valve | Continuity | ||
| Connector | Terminal | Connector | Terminal | |
| F209 | 13 | F207 | 10 | Existed |
| 18 | 13 | |||
| 22 | 11 | |||
Repair or replace malfunctioning parts.
There is malfunction of primary pressure sensor. Replace control valve assembly. Refer to Removal and Installation
.