With M.U.T.-III SE| Monitor item | Test condition | Condition |
| D POSITION SW | Shift position: “D” position | On |
| Other than the above | Off | |
| N POSITION SW | Shift position: “N” position | On |
| Other than the above | Off | |
| R POSITION SW | Shift position: “R” position | On |
| Other than the above | Off | |
| P POSITION SW | Shift position: “P” position | On |
| Other than the above | Off |
Without M.U.T.-III SE| + | − | Test condition | Voltage | |
| TCM | ||||
| Connector | Terminal | |||
| F75 | 4 | Ground | Shift position: “D” position | 10 – 16 V |
| Other than the above | Approx. 0 V | |||
| 5 | Shift position: “N” position | 10 – 16 V | ||
| Other than the above | Approx. 0 V | |||
| 6 | Shift position: “R” position | 10 – 16 V | ||
| Other than the above | Approx. 0 V | |||
| 7 | Shift position: “P” position | 10 – 16 V | ||
| Other than the above | Approx. 0 V | |||
Check intermittent incident. Refer to Intermittent IncidentIntermittent Incident
.
-1“D POSITION SW” is “ON” when selector is not in “D” position. Or connector terminal 4 is at power voltage :
.
-2“N POSITION SW” is “ON” when selector is not in “N” position. Or connector terminal 5 is at power voltage :
.
-3 “R POSITION SW” is “ON” when selector is not in “R” position. Or connector terminal 6 is at power voltage :
.
-4“P POSITION SW” is “ON” when selector is not in “P” position. Or connector terminal 7 is at power voltage :
.| TCM | Continuity | ||
| Connector | Terminal | ||
| F75 | 4 | 2 | Not existed |
| 5 | |||
| 6 | |||
| 7 | |||
Repair or replace malfunctioning parts.| + | − | Voltage (Approx.) | |
| TCM | |||
| Connector | Terminal | ||
| F75 | 4 | Ground | 0 V |
Repair or replace malfunctioning parts.| TCM | Continuity | ||
| Connector | Terminal | ||
| F75 | 5 | 2 | Not existed |
| 4 | |||
| 6 | |||
| 7 | |||
Repair or replace malfunctioning parts.| + | − | Voltage (Approx.) | |
| TCM | |||
| Connector | Terminal | ||
| F75 | 5 | Ground | 0 V |
Repair or replace malfunctioning parts.| TCM | Continuity | ||
| Connector | Terminal | ||
| F75 | 7 | 2 | Not existed |
| 4 | |||
| 5 | |||
| 6 | |||
Repair or replace malfunctioning parts.| + | − | Voltage (Approx.) | |
| TCM | |||
| Connector | Terminal | ||
| F75 | 7 | Ground | 0 V |
Repair or replace malfunctioning parts.| TCM | Continuity | ||
| Connector | Terminal | ||
| F75 | 6 | 2 | Not existed |
| 4 | |||
| 5 | |||
| 7 | |||
Repair or replace malfunctioning parts.| + | − | Voltage (Approx.) | |
| TCM | |||
| Connector | Terminal | ||
| F75 | 6 | Ground | 0 V |
Repair or replace malfunctioning parts.
.
Check intermittent incident. Refer to Intermittent IncidentIntermittent Incident
.
Repair or replace malfunctioning parts.