![[Previous]](../../../buttons/fprev.png)
![[Next]](../../../buttons/fnext.png)
With M.U.T.-III SE| Clicking sound should be heard. |
| + | − | Voltage | |
| EVAP canister vent control valve | |||
| Connector | Terminal | ||
| C52 | 1 | Ground | Battery voltage |
| + | − | Continuity | ||
| EVAP canister vent control valve | IPDM E/R | |||
| Connector | Terminal | Connector | Terminal | |
| C52 | 1 | F35 | 78 | Existed |
Perform the trouble diagnosis for power supply circuit.
Repair or replace error-detected parts.| + | − | Continuity | ||
| EVAP canister vent control valve | ECM | |||
| Connector | Terminal | Connector | Terminal | |
| C52 | 2 | E16 | 149 | Existed |
Repair or replace error-detected parts.
Clean the rubber tube using an air blower.
.
Check intermittent incident. Refer to Intermittent IncidentIntermittent Incident
.
Replace EVAP canister vent control valve. Refer to Removal and Installation
.