| DTC | M.U.T.-III SE screen terms (Trouble diagnosis content) | DTC detection condition | |||
| P0136 | 00 | O2 sensor bank 1 sensor 2 (O2 Sensor Circuit Bank 1 Sensor 2) | A | Diagnosis condition | — |
| Signal (terminal) | Heated oxygen sensor 2 signal | ||||
| Threshold | An excessively high voltage from the sensor is sent to ECM | ||||
| Diagnosis delay time | — | ||||
| B | Diagnosis condition | — | |||
| Signal (terminal) | Heated oxygen sensor 2 signal | ||||
| Threshold | The minimum voltage from the sensor is not reached to the specified voltage | ||||
| Diagnosis delay time | — | ||||
Refer to DTC Diagnosis Procedure
.
-1With M.U.T.-III SE:
.
-2Without M.U.T.-III SE:
.| note | For better results, perform “DTC WORK SUPPORT” at a temperature of 0 to 30°C (32 to 86°F). |
| note | It will take at most 10 minutes until “COMPLETED” is displayed. |
INSPECTION END
Refer to DTC Diagnosis Procedure
.
.| note | Use component function check to check the overall function of the heated oxygen sensor 2 circuit. During this check, a 1st trip DTC might not be confirmed. |
-1To check malfunction symptom before repair: Refer to Intermittent IncidentIntermittent Incident
.
-2Confirmation after repair: INSPECTION END
Proceed to DTC Diagnosis Procedure
.