1.CHECK ELECTRIC INTAKE VALVE TIMING (IVT) CONTROL POSITION SENSOR CIRCUIT
- Turn ignition switch OFF.
- Disconnect electric IVT control position sensor harness connector.
- Disconnect electric IVT control module harness connector.
- Check the continuity between electric IVT control position sensor harness connector and electric IVT control module harness connector.
| Electric IVT control position sensor | Electric IVT control module | Continuity |
| Connector | Terminal | Connector | Terminal |
| F92 | 3 | F90 | 9 | Existed |
| 4 | 35 |
| 5 | 6 |
- Check harness for short to power and short to ground.
Is the inspection result normal?
Repair or replace error-detected parts.