| ECM | ||
| Connector | Terminal | |
| F52 | 120 | 106 |
| note |
|
| note | As the atmospheric pressure described on the synoptic chart is the value at sea level, compensate the pressure with the following chart. |
| Altitude (m) | Compensated pressure (hPa) |
| 0 | 0 |
| 200 | −24 |
| 400 | −47 |
| 600 | −70 |
| 800 | −92 |
| 1000 | −114 |
| 1500 | −168 |
| 2000 | −218 |
| Atmospheric pressure (hPa) | Voltage (V) |
| 800 | 3.1 – 3.7 |
| 850 | 3.3 – 3.9 |
| 900 | 3.5 – 4.1 |
| 950 | 3.8 – 4.3 |
| 1000 | 4.0 – 4.6 |
| 1050 | 4.2 – 4.8 |
Replace MAP sensor. Refer to Removal and InstallationExploded View
.| ECM | ||
| Connector | Terminal | |
| F52 | 120 | 106 |
| Intake manifold vacuum [kPa (mmHg)] | Voltage difference |
| −40 (−300) | 1.5 – 2.0 V |
| −53.3 (−400) | 2.0 – 2.6 V |
| −66.7 (−500) | 2.6 – 3.2 V |
| −80 (−600) | 3.2 – 3.8 V |
INSPECTION END
Replace MAP sensor. Refer to Removal and InstallationExploded View
.